Standard Inverter Specifications
The standard Inverter specifications are listed by capacity in the following tables.
Specifications by Model
Specifications are given by model in the following tables.
200V Class
* 1. The maximum applicable motor output is given for a standard 4-pole Yaskawa motor. When selecting the actual motor and Inverter, be sure that the Inverter's
rated current is applicable for the motor's rated current.
* 2. A transformer with dual star-delta secondary is required on the power supply for 12-pulse rectification.
Table 8.1 200 V Class Inverters
Model Number CIMR-L7C
23P7
25P5
27P5
2011
2015
2018
2022
2030
2037
2045
2055
Max. applicable motor output
(kW)
*1
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
Rated output capacity
(kVA)
7
10
14
20
27
33
40
54
67
76
93
Rated output current (A)
17.5
25
33
49
64
80
96
130
160
183
224
Max. output voltage (V)
3-phase; 200, 208, 220, 230, or 240 VAC
(Proportional to input voltage.)
Max. output frequency
(Hz)
Up to 120Hz available by programing.
Rated voltage (V)
Rated frequency (Hz)
3-phase, 200/208/220/230/240 VAC, 50/60 Hz
Rated input current (A)
21
25
40
52
68
96
115
156
176
220
269
Allowable voltage fluctua-
tion
+ 10%, - 15%
Allowable frequency fluc-
tuation
±5%
Measures
for power
supply
harmonics
DC reactor
Optional
−
12-pulse rec-
tification
Not possible
O
ut
put
rat
ing
s
Pow
er s
upp
ly c
har
act
er
ist
ics
C
on
tro
l
ch
ar
act
er
ist
ics
http://nicontrols.com
Summary of Contents for Varispeed L7
Page 3: ...http nicontrols com...
Page 55: ...2 30 http nicontrols com...
Page 129: ...4 62 http nicontrols com...
Page 197: ...5 68 http nicontrols com...
Page 219: ...6 22 http nicontrols com...
Page 243: ...9 14 http nicontrols com...