User Constants
9-
11
9
H3-06
AI-14B CH3 input gain
100.0%
H3-07
AI-14B CH3 input bias
0.0%
H3-08
AI-14B CH2 signal level selection
2
H3-09
AI-14B CH2 function selection
3
H3-10
AI-14B CH2 input gain
100.0 %
H3-11
AI-14B CH2 input bias
0.0 %
H3-12
Analog input filter time constant for the AI-14B
0.03 s
H3-15
Terminal A1 function selection
0
H3-16
Terminal A1 input gain
100.0%
H3-17
Terminal A1 input bias
0.0%
H5-01
Station address
1F
H5-02
Communication speed selection
3
H5-03
Communication parity selection
0
H5-04
Stopping method after communication error
3
H5-05
Communication error detection selection
1
H5-06
Send wait time
5 ms
H5-07
RTS control ON/OFF
1
L1-01
Motor protection selection
1
L1-02
Motor protection time constant
1.0 min
L2-05
Undervoltage detection level
190 V
L2-11
Battery Voltage
0V
L3-01
Stall prevention selection during accel
1
L3-02
Stall prevention level during accel
150 %
L3-05
Stall prevention selection during running
1
L3-06
Stall prevention level during running
150 %
L4-01
Speed agreement detection level
0.0 Hz
L4-02
Speed agreement detection width
2.0 Hz
L4-03
Speed agreement detection level (+/-)
0.0 Hz
L4-04
Speed agreement detection width (+/-)
2.0 Hz
L4-05
Operation when frequency reference is missing
0
L4-06
Frequency reference value at frequency reference loss
80 %
L5-01
Number of auto restart attempts
2
L5-02
Auto restart operation selection
1
L6-01
Torque detection selection 1
0
L6-02
Torque detection level 1
150 %
L6-03
Torque detection time 1
0.1 s
L6-04
Torque detection selection 2
0
Table 9.1 User Constants
No.
Name
Factory
Setting
Setting
http://nicontrols.com
Summary of Contents for Varispeed L7
Page 3: ...http nicontrols com...
Page 55: ...2 30 http nicontrols com...
Page 129: ...4 62 http nicontrols com...
Page 197: ...5 68 http nicontrols com...
Page 219: ...6 22 http nicontrols com...
Page 243: ...9 14 http nicontrols com...