User Parameter Tables
4
-
9
4
User-set Parameters: A2
The parameters set by the user are listed in the following table.
A1-05
Password
setting
Used to set a four digit number
as the password.
Usually this parameter is not
displayed. When the Password
(A1-04) is displayed, hold
down the RESET key and
press the Menu key. The pass-
word will be displayed.
0 to
9999
0
No
A
A
A
105H
5-60
Select Pass-
word
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Display
A2-01
to
A2-32
User speci-
fied parame-
ters
Used to select the function for
each of the user specified
parameters. User parameters are
the only accessable parameters
if Parameter Access Level is set
to user parameters (A1-01=1)
b1-01 to
S3-01
–
No
A
A
A
106H to
125H
5-61
User Param 1
to 32
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/
f
Open
Loop
Vector
Closed
Loop
Vector
Display