5
-64
Battery Operation
Using battery operation the car can be moved to the next floor if the power supply fails. The battery operation,
must be enabled by a digital input (H1-
= 85).
The battery voltage must be set in parameter L2-11.
Related Constants.
Multi-function Digital Inputs (H1-01 to H1-05)
Battery operation wiring
Parameter
No.
Name
Factory
setting
Change
during
operation
V/f
Open
Loop
Vector
Closed
Loop
Vector
L2-11
Battery Voltage
0V
No
A
A
A
Setting
Function mane
V/f
Open
Loop
Vector
Closed
Loop
Vector
85
Battery operation command
A
A
A
SoftCharge
Resistor
P
R
S
T
P
N
Sx
SC
Contorl Power
Battery Operation
setting 85
U
V
W
E
200VClass(DC250V 300V)
400VClass(DC500V 600V)
A
C
A
A
D
B
E
http://nicontrols.com