7.2 V/f Control without PG
7 - 11
7.2 V/f Control without PG
The functions that can be used with vector control without PG are listed in
Table 7.2.
Details on functions that
are specific to vector control without PG (i.e. those marked with a
L
) are provided in the following table.
Table
7.2
Normal V/f Control Functions
Control Meth-
od
Group
Function
Comments
V/f
V/f
w/PG
Open-loop
V
ector
Flux
V
ector
b1
Sequence
Settings such as the reference input method
f
f
f
f
b2
DC Injection Braking
DC injection braking function settings
f
f
f
f
b3
Speed Search
Speed search function settings
f
f
f
f
b4
Delay Timers
Timer function settings
f
f
f
f
b Application
b5
PID Control
PID control settings
f
f
f
f
b Application
b6
Dwell Functions
Acceleration/deceleration time dwell function settings
f
f
f
f
b7
Droop Control
Not used. (Can’t be set.)
×
×
×
f
b8
Energy Saving
L
Multi-function input: Energy-saving control settings
f
f
×
×
b9
Zero Servo
Not used. (Can’t be set.)
×
×
×
f
C1
Accel/Decel
Acceleration/deceleration time settings
f
f
f
f
C2
S-Curve Acc/Dec
S-curve characteristics for accel/decel times
f
f
f
f
C3
Motor-Slip Compensation
Slip compensation function settings
f
f
f
f
C Tuning
C4
Torque Compensation
Torque compensation function settings
f
f
f
×
C Tuning
C5
Speed Controls
Not used. (Can’t be set.)
×
f
×
f
C6
Carrier Frequency
Carrier frequency settings
f
f
f
f
C7
Hunting Prevention
L
Hunting prevention function settings
f
f
×
×
C8
Factory Tuning
Not used. (Can’t be set.)
×
×
f
×
d1
Preset Reference
Frequency reference settings (when using Operator)
f
f
f
f
d2
Reference Limits
Frequency upper and lower limit settings
f
f
f
f
d Reference
d3
Jump Frequencies
Prohibited frequency settings
f
f
f
f
d Reference
d4
Reference Frequence Hold
Function
Up/Down, Accel/Decel stop hold frequency setting
f
f
f
f
d5
Torque Control
Not used. (Can’t be set.)
×
×
×
f
E1
V/f Pattern
L
Motor constant settings
f
f
f
f
E2
Motor Setup
L
Motor constant settings
(Motor constants set manually.)
f
f
f
f
E Motor
E3
Motor 2 Control Methods
Control method settings for motor 2.
f
f
f
f
E Motor
E4
Motor 2 V/f Characteristics
V/f characteristics settings for motor 2.
f
f
f
f
E5
Motor 2 Motor Constants
Motor constant settings for motor 2.
f
f
f
f
F1
PG speed control card set-
tings
Not used. (Can’t be set.)
×
f
×
f
F2
Analog Reference Card AI
User constant settings for an Analog Reference Card
f
f
f
f
F3
Digital Reference Card DI
User constant settings for a Digital Reference Card
f
f
f
f
F4
Analog Monitor Card AO
User constant settings for an Analog Monitor Card
f
f
f
f
F Options
F5
Digital Output Card DO
User constant settings for a Digital Output Card
f
f
f
f
F Options
F6
Digital Output Card DO
User constant settings for a Digital Output Card
f
f
f
f
F7
Pulse Monitor Card PO
User constant settings for a Pulse Monitor Card
f
f
f
f
F8
SI-F/SI-G Transmission
Card
User constant settings for a Transmission Card
f
f
f
f
F9
Transmission Cards other
than SI-K2 and SI-F/G
User constant settings for a Transmission Card
f
f
f
f
H1
Multi-function Inputs
Function selection for multi-function inputs
f
f
f
f
H2
Multi-function Outputs
Function selection for multi-function outputs
f
f
f
f
H T
i l
H3
Analog Inputs
Function selection for analog inputs
f
f
f
f
H Terminal
H4
Multi-function Analog Out-
puts
Function selection for analog outputs
f
f
f
f
H5
MEMOBUS Communica-
tions
MEMOBUS communications settings
−
−
−
−
7