![YASKAWA SI-EL3 Technical Manual Download Page 28](http://html2.mh-extra.com/html/yaskawa/si-el3/si-el3_technical-manual_3208824028.webp)
8 Object Dictionary
28
YASKAWA EUROPE GMBH
YEU SIEP C710616 86A - AC Drive A1000 Option Powerlink - Technical Manual
2270 (Hex) - Drive DI Input
This object can be used to display the input terminal status.
4000 (Hex) - Option NVS FATAL Record
Internal FATAL NVS record for debugging purposes.
Note: Writing 0xFB to sub-index 0 will clear the record in NVS memory.
4001 (Hex) - Option Info + Status Record
Provides general information of option system firmware parts and internal system states.
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
2270
0
Number of entries
-
Read Only
-
-
1
Value
-
Read Only
Tx
Unsigned 16
2
MEMOBUS/Modbus register address of content
0049 (Hex)
Read Only
No
Unsigned 16
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
4000
-
Information regarding a system failure/crash is stored
in this object and can be read out for on-site
troubleshooting.
-
Read/Write
No
Unsigned 8
1
Total number of FATAL events logged since entry was
cleared.
-
Read Only
No
Unsigned 32
2
Boot firmware revision in flash when the last event
was logged.
-
Read Only
No
Unsigned 16
3
Application firmware revision in flash when the last
event was logged
-
Read Only
No
Unsigned 32
4
Option internal enumerated status code of the logged
event.
-
Read Only
No
Unsigned 16
5
Event specific parameter value associated with the
status event.
-
Read Only
No
Unsigned 16
6
NOI System active error bits when event occurred.
-
Read Only
No
Unsigned 16
7
NOI System latched (All errors that have occurred
since start-up) error bits.
-
Read Only
No
Unsigned 16
8
INV status word when the last error was logged.
-
Read Only
No
Unsigned 16
9
Last error logged in object 0x603F.
-
Read Only
No
Unsigned 16
10
Event number parameter associated with FATAL
event.
-
Read Only
No
Unsigned 32
11
Total running time in milliseconds of option system
since power-up to the FATAL event was triggered.
-
Read Only
No
Unsigned 32
12
Internal system Task ID enumeration that causes the
FATAL event.
-
Read Only
No
Unsigned 16
13
Line in source-code file where the FATAL event was
triggered.
-
Read Only
No
Unsigned 16
14
Name of source-code file where the FATAL event was
triggered.
-
Read Only
No
Visible String
Index (Hex)
Subindex
Content
Default
Access
PDO Mapping
Data Length
4001
0
Provides general information of option system
firmware parts and internal system states.
-
Read Only
No
Unsigned 8
1
Boot firmware revision in flash.
Value: 0x00AABBCC
AA = Major revision
BB = Minor revision
CC = Build
-
Read Only
No
Unsigned 32
2
Application firmware revision in flash.
Value: 0x00AABBCC
AA = Major revision
BB = Minor revision
CC = Build
-
Read Only
No
Unsigned 32
3
Total running time in milliseconds of option system
since power-up.
-
Read Only
No
Unsigned 32
4
NOI System active error bits.
-
Read Only
No
Unsigned 16
5
NOI System latched (All errors that have occurred
since start-up) error bits.
-
Read Only
No
Unsigned 16
6
MAC address assigned during manufacturing.
-
Read Only
No
Octet string
Summary of Contents for SI-EL3
Page 2: ......