10 Inspection, Maintenance, and Troubleshooting
10.4.2 List of Parameters
10-40
* Used only for SGDJ-
P SERVOPACK for position control mode.
Param-
eter No.
Name
Setting Range
Units
Factory Setting
Setting
Validation
Reference
Section
S
P
Pn406
Emergency Stop Torque
0 to 800%
1%
800
800
Immedi-
ately
8.3.3
Pn407
Speed Limit during Torque Control
0 to 10000 min
-1
1 min
-1
10000
−
Immedi-
ately
8.7.4
Pn408
Torque Function Switches
0000 to 0101
−
0000
0000
Immedi-
ately
9.4.9
Pn409
Notch Filter Frequency
50 to 2000 Hz
1 Hz
2000
2000
Immedi-
ately
9.4.9
Pn500
Positioning Completed Width *
0 to 250 reference
units
1 reference
unit
−
7
Immedi-
ately
8.6.5
Pn501
Zero Clamp Level
0 to 10000 min
-1
1 min
-1
10
−
Immedi-
ately
8.5.6
Pn502
Rotation Detection Level
1 to 10000 min
-1
1 min
-1
20
−
Immedi-
ately
8.11.3
Pn503
Speed Coincidence Signal Output Width
0 to 100 min
-1
1 min
-1
10
−
Immedi-
ately
8.5.8
Pn504
NEAR Signal Width *
1 to 250 reference
units
1 reference
unit
−
7
Immedi-
ately
8.6.6
Pn505
Overflow Level *
1 to 8388352
1 reference
unit
−
1024
Immedi-
ately
9.3.3
Pn506
Brake Reference
-
Servo OFF Delay Time 1 to 50 (10 to 500 ms)
10 ms
0
0
Immedi-
ately
8.3.4
Pn507
Brake Reference Output Speed Level
0 to 10000 min
-1
1 min
-1
100
100
Immedi-
ately
8.3.4
Pn508
Timing for Brake Reference Output during
Motor Operation
10 to 100
(100 to 1000 ms)
10 ms
500
500
Immedi-
ately
8.3.4
Pn509
Momentary Hold time
20 to 1000 ms
1 ms
20
20
Immedi-
ately
8.3.6
0
1
N/A
Uses a notch filter for torque reference.
Notch Filter Selection
(Refer to "9.4.9 Torque Reference Filter.")
Reserved (Do not change)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Reserved (Do not change)
Reserved (Do not change)