n.X
Reserved parameter (Do not change.)
Param-
eter No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn514
2
Output Signal
Selections 4
0000h to
0666h
–
0000h
All
After
restart
Setup
–
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
/PM (Preventative Maintenance Output) Signal Allo-
cation
Reference
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output
terminal.
2
Output the signal from the CN1-23 or CN1-24
output terminal.
3
Output the signal from the CN1-25 or CN1-26
output terminal.
4 to
6
Reserved setting (Do not use.)
n.X
Reserved parameter (Do not change.)
Param-
eter No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn516
2
Input Signal
Selections 7
0000h to
FFFFh
–
8888h
All
After
restart
Setup
–
n.
X
FSTP (Forced Stop Input) Signal Allocation
Reference
0
Enable drive when CN1-13 input signal is ON
(closed).
1
Enable drive when CN1-7 input signal is ON
(closed).
2
Enable drive when CN1-8 input signal is ON
(closed).
3
Enable drive when CN1-9 input signal is ON
(closed).
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en |
716