Mode Switching Level for Position Deviation
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn10F
0 to 10,000
1 reference
unit
0
Immediately
Tuning
(applies to Position Control)
n
Linear Servomotors
Mode Switching Level for Force Reference
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn10C
0 to 800
1%
200
Immediately
Tuning
(applies to Speed Control and Position Control)
Mode Switching Level for Speed Reference
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn181
0 to 10,000
1 mm/s
0
Immediately
Tuning
(applies to Speed Control and Position Control)
Mode Switching Level for Acceleration
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn182
0 to 30,000
1 mm/s
2
0
Immediately
Tuning
(applies to Speed Control and Position Control)
Mode Switching Level for Position Deviation
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn10F
0 to 10,000
1 reference
unit
0
Immediately
Tuning
(applies to Position Control)
Using the Internal Torque Reference as the Mode Switching Condition (Default Set-
ting)
When the Internal torque reference equals or exceeds the torque set for the mode
switching level for torque reference (Pn10C), the speed loop is changed to P control.
The default setting for the torque reference level is 200%.
Sigma-7 Series SERVOPACKs
Tuning
Manual Tuning > Compatible Adjustment Functions
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en |