Pin No.
Signal
Function
5
PS
Serial data (+)
6
/PS
Serial data (-)
Shell
Shield
–
* No wiring is required for an incremental encoder or a batteryless absolute encoder.
n
When Using a Direct Drive Servomotor
Pin No.
Signal
Function
1
PG5V
Encoder power 5 V
2
PG0V
Encoder power supply 0 V
3
–
– (Do not use.)
4
–
– (Do not use.)
5
PS
Serial data (+)
6
/PS
Serial data (-)
Shell
Shield
–
n
When Using a Linear Servomotor
Pin No.
Signal
Function
1
PG5V
Linear encoder power 5 V
2
PG0V
Linear encoder power supply 0 V
3
-
– (Do not use.)
4
-
– (Do not use.)
5
PS
Serial data (+)
6
/PS
Serial data (-)
Shell
Shield
–
5.5.3 Wiring the SERVOPACK to the Encoder
5.5.3.1
When Using an Absolute Encoder
If you use an absolute encoder, use an Encoder Cable with a JUSP-BA01-E Battery Case
or install a battery on the host controller.
Refer to the following section for the battery replacement procedure.
Chap. 16.2.4 ‘Replacing the Battery’ page 580
Sigma-7 Series SERVOPACKs
Wiring and Connecting SERVOPACKs
Wiring Servomotors > Wiring the SERVOPACK to the Encoder
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en |