10-1
165553-1CD
HW1482183
10 Sensor Parameters (SxE)
Conveyor Synchronized
Funciton with Shift
Functions
10 Sensor Parameters (SxE)
Use the sensor parameters with their initial value settings.
No.
Contents
Initial Value
0
Application designation
16
1
Time to recognize the input of start signal
1)
1 The time to recognize the input of start signal (S1E) indicates the time from
the moment that the conveyor home-position limit switch turns ON until the
DX200 confirms the conveyor home-position limit switch ON input signal. The
setting range is from 1 to 1000.
Use the parameter S1E with its initial setting. However, if the conveyor home-
position limit switch malfunction occurs frequently, change the setting to a
bigger value as required.
5
2
Reference time to recognize the occurrence of speed
down
100
3
Time for averaging the speed variation amount
60
4
Time to recognize the falling edge of start signal
5
13
Maximum workpiece position (0 to 2000m)
2)
0 corresponds to 21 m
2 The maximum workpiece position indicates the distance between the
workpiece position and the manipulator start position. When a workpiece is
carried for this distance from the manipulator start position, the DX200
automatically deletes the workpiece information from the job queue or issues
the alarm. Whether to automatically delete the information or issue the alarm
can be selected by the setting of the sensor parameter No.14 “Data overflow
alarm specification.”
While the conveyor synchronization is not executed, however, the workpiece
information is automatically deleted from the job queue regardless of the
setting of the sensor parameter No.14.
0
14
Data overflow alarm specification Specifies the action
to be taken when a workpiece is carried for the
distance set in SxE13.
0: Alarm occurrence
1: No alarm occurrence
0
15
Manual setting function for conveyor home-position
limit switch
0: Valid only when using a virtual encoder
1: Valid when using a encoder as well
0
16
Ignorance of shift distance in virtual conveyor mode
Specifies whether the start shift distance is to be “0” or
not in the virtual conveyor mode.
0: Validates the start shift distance
1: Invalidates the start shift distance (set to 0)
0
17
Output time of detection signal for disconnection
Sets the time during which the conveyor
synchronization board sends the signal to the main
CPU when a disconnection of the conveyor pulse
signal is detected.
Units: ms
0
97 of 98