![YASKAWA Motoman DX200 Instructions Manual Download Page 25](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282025.webp)
2-5
165553-1CD
HW1482183
2
Conveyor Condition File
2.1 Conveyor Condition File
Conveyor Synchronized
Funciton with Shift
Functions
(17) VIRTUAL ENCODER IN (0 to 4096)
Set the general-purpose input signal number to be set for the virtual
encoder. When this signal is input, the encoder input enters the virtual
encoder mode.
000 : Virtual encoder not used
001 to 4096: The general-purpose input signal of the set number
activates the virtual encoder mode.
(18) VIRTUAL ENCODER OUT (0 to 4096)
When “VIRTUAL ENCODER” is selected in (5), set the general-purpose
output signal number to be set for the virtual encoder output.
000 : Virtual encoder not used
001 to 4096: The general-purpose output signal of the set number is
output from the virtual encoder
(19) TRACKING CORRECTION (-500 to 1000 msec)
Set the tracking correction time.
*Displayed on version DN1.60-000 and later.