![YASKAWA Motoman DX200 Instructions Manual Download Page 35](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282035.webp)
2-15
165553-1CD
HW1482183
2
Conveyor Condition File
2.8 WORK ID SHIFT Condition File
Conveyor Synchronized
Funciton with Shift
Functions
2.8
WORK ID SHIFT Condition File
(1) FILE NO.
Displays the WORK ID SHIFT condition file.
(2) USED STATUS (USED/NOT USED)
Specify whether the WORK ID SHIFT condition file is used or not.
(3) PORT NO. (CN1/CN2/CN3)
Displays the port number where the WORK ID detecting limit switch is
connected.
(4) CHATTERING PRVNT DIS (0 to 9999.9 mm)
Set a distance to prevent the repeated inputs of the WORK ID detecting
limit switch signal due to the limit switch chattering. While the conveyor
moves for the set distance from the moment the WORK ID detecting
limit switch signal is input, another WORK ID detecting limit switch
signal is ignored.
Set “0” to disable monitoring for the chattering prevention distance and
to count the number of workpieces with every input.
(5) CHATTERING PRVNT TIME (0 to 999.9 sec)
Set a time to prevent the repeated inputs of the WORK ID detecting limit
switch signal due to the limit switch chattering. Until the set time passes
from the moment the WORK ID detecting limit switch signal is input,
another WORKD ID detecting limit switch signal is ignored.
Set “0” to disable monitoring for the chattering prevention time and to
count the number of workpieces with every input. If both the distance
and the time for the chattering prevention are set, the larger one is
applied.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
35 of 98