![YASKAWA Motoman DX200 Instructions Manual Download Page 23](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282023.webp)
2-3
165553-1CD
HW1482183
2
Conveyor Condition File
2.1 Conveyor Condition File
Conveyor Synchronized
Funciton with Shift
Functions
(7) CORRECTION (FORWARD/REVERSE)
Specify if the direction of the follow-up motion should be reversed or not.
If “REVERSE” is selected, the sign of the correction position on the
conveyor speed display is reversed and the manipulator executes the
follow-up motion in the reversed direction.
(8) TRACKING (ROBOT AXIS/BASE AXIS)
Specify whether the manipulator is synchronized with the robot axis or
the base axis (travel axis). If “BASE AXIS” is selected for the system
without base axis, no synchronized motion can be performed.
(9) USER COORD NO. (1 to 63)
When “ROBOT AXIS” is selected in (8), specify the user coordinate
number in whose X-axis direction the manipulator moves in
synchronization with the conveyor movement.
(10) BASE AXIS (X/Y/Z)
When “BASE AXIS” is selected in (8), specify X-, Y-, or Z-axis to move
in synchronization with the conveyor movement.
(11) POS RESOLUTION (0 to 999.99
μ
m/pulse)
This data convert one pulse from the encoder to the conveyor travel
amount (
μ
m).
For the details of setting method, refer to “4.3 Setting of Conveyor
Positional Resolution” of “DX200 OPTIONS INSTRUCTIONS FOR
CONVEYOR SYNCHRONIZED FUNCTION.”
(12) VIRTUAL CV SPEED (-3276.8 to +3276.7 mm/s)
When “VIRTUAL ENCODER” is selected in (5), set the virtual encoder
speed.
Manipulator
Follow-up motion
Conveyor moving direction
FORWARD
REVERSE
Manipulator
Follow-up motion
Conveyor moving direction
23 of 98