Conveyor Condition File
2.10 WORK IN/NOT SHIFT Condition File
Conveyor Synchronized
Funciton with Shift
Functions
(7) MAX. WORK CNT (1 to 99)
Set the maximum number of workpieces that are set between the
WORK IN/NOT detecting limit switch to the reference workpiece for
synchronization start.
(8) WORK IN/NOT SIG (0 to 4096)
Set the general-purpose output signal number that specifies the
presence/absence of workpiece.
Manipulator start position
Conveyor moving direction
WORK IN/NOT
detecting limit switch
Manipulator
MAX. WORK FIND COUNT