![YASKAWA Motoman DX200 Instructions Manual Download Page 61](http://html.mh-extra.com/html/yaskawa/motoman-dx200/motoman-dx200_instructions-manual_907282061.webp)
3-19
165553-1CD
HW1482183
3
Teaching
3.8 Job Examples
Conveyor Synchronized
Funciton with Shift
Functions
3.8.4 Job Example Using the Start Shift, WORK ID Shift, and WORK IN/
NOT Shift Functions (New Shipment at DN1.60-00 or Later)
An example of the job using all the shift functions (Start Shift, WORK ID
Shift, and WORK IN/ NOT Shift) is given as follows.
Master Job
Set “USED” for the START SHIFT, WORK ID. SHIFT, and WORK IN/NOT
SHIFT of the CONVEYOR COND SUPP. file.
Instruction
Description
0000
NOP
0001
SYEND CV#(1)
Resets the registered status of the conveyor’s home
position.
The conveyor home-position limit switch become valid.
0002
*TOP
0003
MOVJ VJ=50.00
Moves the manipulator to the stand-by position.
0004
GETCVSFT CV#(1) QUENO=1
WKKIND I000 WKEXIST I001
RESULT B010
Gets the synchronizable queue information.
0005
JUMP *TOP IF B010<>0
If information cannot be obtained with GETCVSFT, jumps
to [*TOP].
0006
JUMP *END IF I001=0
If the WORK IN/NOT information is NOT, jumps to [*END].
0007
SYSTART CV#(1) STP=100.00
OL=100.0
Start instruction for the conveyor synchronization.
Starts the conveyor synchronized control when the
conveyor reaches the specified position.
0008
GETS B000 $B008
The system variable to indicate whether the
synchronization has started normally or not
The contents of $B008 is copied to B000:
Synchronization started normally if B000=1, and an error
occurred if B000=0
0009
JUMP *SYEND IF B000=0
If B000=0 (the synchronization did not start normally),
jumps to the label [*SYEND].
0010
CALL JET#(1) ENTRY=I000
Reads the WORK ID information stored in I000, and starts
the I000 registered job in the job registration table.
0011
*SYEND
0012
SYEND CV#(1)
Ends the synchronization.
0013
*END
0014
CVQUE CV#(1)
Switches the reference workpiece for synchronization.
0015
JUMP *TOP
0016
END
NOTE
Be sure to program the SYEND instruction at the beginning
of the master job to reset the registered status of the
conveyor’s home position.
61 of 98