10.2 Operating Inverters Using an MPE720
10.2.3 Operation Procedure
10-6
10.2.3 Operation Procedure
Connect the inverter to the Machine Controller through MECHATROLINK-I or MECHATROLINK-II, and then carry
out the following operations:
1.
Execute the Machine Controller self-configuration.
The inverter will be allocated to the Machine Controller’s SVB Definition.
The inverter can be also manually allocated. Refer to
10.2.4 Manually Allocating Inverters
for details.
2.
Start the MPE720 (version 5.12 or later) in the personal computer connected to the Machine Controller,
and open the Module Configuration Window.
Refer to
3.4.1 ( 1 ) How to Open the Module Configuration Window
for more information.
3.
Double-click the
Slot Number
cell of the
SVB
column in the Module Details field.
The SVB Definition Window will open.
4.
Confirm that
INVERTER
and
VS-7SERIES
are selected for the axis type, then click the
Monitor
Tab.
The Monitor Tab Page will open.