11 Appendix
11-30
Pn122
0 Hz
Reserved (Do not change)
Immediately
Pn123
0%
Reserved (Do not change)
Immediately
Pn124
100 ms
Automatic Gain Switching Timer
Immediately
Pn125
7 reference
units
Automatic Gain Switching Width
Immediately
Pn200
0000
Position Control References Selection
Switches
After restart
Pn201
16384 P/rev
PG Dividing Ratio
(For 16-bit or less)
After restart
Pn202
4
Electronic Gear Ratio (Numerator)
After restart
Pn203
1
Electronic Gear Ratio (Denominator)
After restart
Pn204
0.00 ms
Position Reference Accel/Decel Time
Constant
Immediately
Pn205
65535 rev
Multiturn Limit Setting
After restart
Pn206
16384 P/rev
Reserved (Do not change)
−
Pn207
0000
Position Control Function Switches
After restart
Pn208
0.00 ms
Position Reference Movement
Averaging Time
After restart
Pn212
2048 P/rev
PG Dividing Ratio
(For 17-bit or more)
After restart
Pn217
×
1
Reference Pulse Input Multiplication
Immediately
Pn218
0000
Reference Pulse Multiplication Range
Switching Function
After restart
Pn300
6.00 V/
rated speed
Speed Reference Input Gain
Immediately
Pn301
100 min
-1
Internal Set Speed 1
Immediately
Pn302
200 min
-1
Internal Set Speed 2
Immediately
Pn303
300 min
-1
Internal Set Speed 3
Immediately
Pn304
500 min
-1
JOG Speed
Immediately
Pn305
0 ms
Soft Start Acceleration Time
Immediately
Pn306
0 ms
Soft Start Deceleration Time
Immediately
Pn307
0.40 ms
Speed Reference Filter Time Constant
Immediately
Pn308
0.00 ms
Speed Feedback Filter Time Constant
Immediately
Pn309
60 min
-1
Reserved (Do not change)
Immediately
Pn400
3.0 V/
rated speed
Torque Reference Input Gain
Immediately
Pn401
1.00 ms
Torque Reference Filter Time Constant Immediately
Pn402
800%
Forward Torque Limit
Immediately
Pn403
800%
Reverse Torque Limit
Immediately
Pn404
100%
Forward External Torque Limit
Immediately
Pn405
100%
Reverse External Torque Limit
Immediately
Pn406
800%
Emergency Stop Torque
Immediately
Pn407
10000 min
-1
Speed Limit during Torque Control
Immediately
Pn408
0000
Torque Function Switches
Immediately
Pn409
2000 Hz
First Stage Notch Filter Frequency
Immediately
Pn40A
0.70
First Stage Notch Filter Q Value
Immediately
Pn40B
2000 Hz
Second Stage Notch Filter Frequency
Immediately
Pn40C
0.70
Second Stage Notch Filter Q Value
Immediately
Pn500
7 reference
units
Positioning Completed Width
Immediately
Pn501
10 min
-1
Zero Clamp Level
Immediately
Parameter
No.
Factory
Setting
Name
Setting
Validation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com