11.3 List of Parameters
11-21
11
Appendix
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Pn207
Position Control Function Switches
0000 to 1111
−
0000
After restart
Pn208
Position Reference Movement Averaging
Time
0 to 6400
0.01 ms
0
After restart
Pn212
PG Dividing Ratio
(For 17-bit or more)
16 to 1073741824
1 P/rev
2048
After restart
Pn217
Reference Pulse Input Multiplication
1 to 99
×
1
1
Immediately
Pn218
Reference Pulse Multiplication Range
Switching Function
0000 to 0001
−
0000
After restart
Pn300
Speed Reference Input Gain
150 to 3000
0.01V
/ rated speed
600
Immediately
Pn301
Internal Set Speed 1
0 to 10000
1 min
-1
100
Immediately
Pn302
Internal Set Speed 2
0 to 10000
1 min
-1
200
Immediately
Pn303
Internal Set Speed 3
0 to 10000
1 min
-1
300
Immediately
0
1
Acceleration/deceleration
filter
Average movement filter
Reserved (Do not change)
Position Reference Filter Selection
0
1
N/A
Uses V-REF as a speed feed-forward input.
Position Control Option
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0
1
Uses the parameter Pn201 (For 16-bit or less) as the dividing ratio (Factory setting).
Uses the parameter Pn212 (For 17-bit or more) as the dividing ratio.
Dividing Output Range Selection
Reserved (Do not change)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0
1
Disabled (Factory setting)
Enabled
Reference Pulse Input Multiplication Range Switching Function
Reserved (Do not change)
Reserved (Do not change)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com