11 Appendix
11.3.2 List of Parameters
11-24
Input signal polarities
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Pn50B
Input Signal Selections 2
−
−
6543
After restart
0
1
2
3
4
5
6
7
8
9
A
B
Reverse run allowed when CN1-40 input signal is ON (L-level).
Reverse run allowed when CN1-41 input signal is ON (L-level).
Reverse run allowed when CN1-42 input signal is ON (L-level).
Reverse run allowed when CN1-43 input signal is ON (L-level).
Reverse run allowed when CN1-44 input signal is ON (L-level).
Reverse run allowed when CN1-45 input signal is ON (L-level).
Reverse run allowed when CN1-46 input signal is ON (L-level).
Reverse run prohibited.
Reverse run allowed.
Reverse run allowed when CN1-40 input signal is OFF (H-level).
Reverse run allowed when CN1-41 input signal is OFF (H-level).
Reverse run allowed when CN1-42 input signal is OFF (H-level).
0 to F
Same as above
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Reverse run allowed when CN1-43 input signal is OFF (H-level).
Reverse run allowed when CN1-44 input signal is OFF (H-level).
Reverse run allowed when CN1-45 input signal is OFF (H-level).
Reverse run allowed when CN1-46 input signal is OFF (H-level).
C
D
E
F
/P-CL Signal Mapping (Forward Torque Limit when ON (L-level))
0 to F
Same as above
/N-CL Signal Mapping (Reverse Torque Limit when ON (L-level))
N-OT Signal Mapping (Overtravel when OFF (H-level))
/ALM-RST Signal Mapping (Alarm Reset when ON (L-level))
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
ON when CN1-40 input signal is ON (L-level).
ON when CN1-41 input signal is ON (L-level).
ON when CN1-42 input signal is ON (L-level).
ON when CN1-43 input signal is ON (L-level).
ON when CN1-44 input signal is ON (L-level).
ON when CN1-45 input signal is ON (L-level).
ON when CN1-46 input signal is ON (L-level).
Sets signal ON.
Sets signal OFF.
ON when CN1-40 input signal is OFF (H-level).
ON when CN1-41 input signal is OFF (H-level).
ON when CN1-42 input signal is OFF (H-level).
ON when CN1-43 input signal is OFF (H-level).
ON when CN1-44 input signal is OFF (H-level).
ON when CN1-45 input signal is OFF (H-level).
ON when CN1-46 input signal is OFF (H-level).
Signal
Effective Level
Voltage level
Contact
ON
Low (L) level
0 V
Close
OFF
High (H) level
24 V
Open
INFO