11 Appendix
11.3.2 List of Parameters
11-20
* This setting must be changed only for special applications. Do not change this limit inappropriately or
unintentionally.
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Pn200
Position Control References Selection
Switches
−
−
0000
After restart
Pn201
PG Dividing Ratio
(For 16-bit or less)
16 to 16384
1 P/rev
16384
After restart
Pn202
Electronic Gear Ratio (Numerator)
1 to 65535
−
4
After restart
Pn203
Electronic Gear Ratio (Denominator)
1 to 65535
−
1
After restart
Pn204
Position Reference Accel/Decel Time Con-
stant
0 to 6400
0.01 ms
0
Immediately
Pn205
Multiturn Limit Setting *
0 to 65535
1 rev
65535
After restart
Pn206
Reserved (Do not change)
−
−
16384
−
0
1
2
3
4
5
6
7
8
9
Sign + Pulse, positive logic
CW + CCW, positive logic
Phase A + Phase B (
×
1), positive logic
Phase A + Phase B (
×
2), positive logic
Phase A + Phase B (
×
4), positive logic
Sign + Pulse, negative logic
CW + CCW, negative logic
Phase A + Phase B (
×
1), negative logic
Phase A + Phase B (
×
2), negative logic
Phase A + Phase B (
×
4), negative logic
Reference Pulse Form
0
1
2
3
Clears error counter when the signal is at H level.
Clears error counter at the rising edge of the signal.
Clears error counter when the signal is at L level.
Clears error counter at the falling edge of the signal.
Error Counter Clear Signal From
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0
1
2
Clears error counter
at the baseblock
.
Does not clear error counter (Possible to clear error counter only with CLR signal).
Clears error counter
when an alarm occurs
.
Clear Operation
0
1
Reference input filter for line driver signals
Reference input filter for open collector signals
Filter Selection
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com