– 127 –
E
TRBL
ANLS
YAMAHA DIAGNOSTIC SYSTEM
YAMAHA DIAGNOSTIC SYSTEM
CONNECTING THE COMPUTER TO
THE OUTBOARD
Connect:
• Communication cable
1
• Adapter
2
NOTE:
Refer to the Yamaha Diagnostic System
Instruction Manual for details on installing
the software onto an IBM-compatible lap-
top computer
3
.
Connecting steps
(1) Quit any applications that are running,
and then turn off the computer.
(2) Connect the communication cable to
the 3-pin communication coupler of
the outboard, the adapter and the
communication port of your computer.
NOTE:
Use either the COM1 or COM2 port, and if
necessary, set the serial port as specified in
the computer’s manual. Set the serial port
where the RS232C (Dsub-9 pin) cable is
connected to COM1 or COM2.
(3) Connect the remote control to the out-
board.
(4) Connect the 12 V battery to the out-
board.
NOTE:
The following items should be checked
before starting the Yamaha Diagnostic Sys-
tem.
• The battery is properly charged and its
specified gravity is within specification.
• There are no incorrect wiring connec-
tions.
• Wiring connections are properly secured
and are not rusty.
• There are enough fuel and oil in each
tank.