– 124 –
–
+
ELEC
E
CHARGING SYSTEM/
POWER TRIM AND TILT SYSTEM
CHARGING SYSTEM
MEASURING THE LIGHTING COIL
OUTPUT PEAK VOLTAGE
Measure:
• Lighting coil output peak voltage
Below specification
→
Replace the
lighting coil.
Lighting coil output peak voltage
Green (G) – Green (G)
r/min
Unloaded
Cranking
1,500
3,500
V
5.5
37
86
Test harness (1-pin)
YB-06788 / 90890-06788
Test harness (2-pin)
YB-06787 / 90890-06787
G
G
8025
POWER TRIM AND TILT SYSTEM
MEASURING THE TRIM SENSOR
RESISTANCE
Measure:
• Trim sensor resistance
Out of specification
→
Replace.
NOTE:
Turn the lever
1
and measure the resis-
tance as it gradually changes.
Trim sensor resistance
Pink (P) – Black (B)
10 - 309
Ω
at 20 ˚C (68 ˚F)
8030