62
STAGEPAS 600i
4. Operation
procedures
* Don’t turn off the power during update.
4-1. Short circuit between pin 3 (UPDATE) and pin 4 (GND)
of connector CN503 on the DSP circuit board, and turn on
the power switch. The
fi
rmware update mode is activated.
* All indicators on the panel do not light at this moment.
* If LED lights or blinks,
it's considered that UPDATE
port on DSP circuit board is not being short-circuited to
GND.
4-2. Execute “UpdaterSTAGEPASII.exe”.
4-3. The “Serial Port” is chosen.
Since the port which can be used is displayed, a use port
is chosen.
4-4. The “Update File” is chosen.
A click of a right-hand side white box will display a
fi
le
selection screen.
4-5. The “Start” button is pushed.
4-6. The “OK” button is pushed and performed after checking,
since version information is displayed.
4-7. The display of a progress bar is updated, and if it becomes
100%, it will complete.
4-8. The “End” button is pushed and an application is ended.
4. 操作方法
※アップデート中は、電源を切らないでください。
4-1. DSP シートのコネクター CN503 の 3 ピン(UPDATE)
と 4 ピン(GND)をショートし、ミキサー Ass'y の
電源をオンすると、ファームウェアアップデート
モードが起動します。
※ このときパネルの全てのインジケータは点灯し
ません。
※ LED が点灯または点滅される場合は、DSP シー
ト上の UPDATE 端子が GND にショートされて
いないことが考えられます。
4-2. 「UpdaterSTAGEPASII.exe」を起動します。
4-3. 「Serial Port」を選択します。
使用可能なポートが表示されるので、使用ポートを
選択します。
4-4. 「Update File」を選択します。
右側の白いボックスをクリックすると、ファイル選
択画面が表示されます。
4-5. 「Start」ボタンを押します。
4-6. バージョン情報が表示されるので、確認してから、
「OK」ボタンを押して、実行します。
4-7. プログレスバーの表示が更新され、100%になった
ら完了します。
4-8. 「End」ボタンを押して、アプリを終了します。