57
STAGEPAS 600i
Measurement condition
(測定条件)
Criteria
(判断基準)
No.
INPUT Terminal
(入力端子)
Connected resistance
(抵抗値)
OUTPUT Terminal
(出力端子)
Measure the noise Level
(ノイズレベルを測定)
(1)
CH1 XLR, 2 pin(Hot)-3 pin(Cold)
150
Ω
MONITOR L
That less than -50 dBu.
(
-50 dBu
以下のこと。)
(2)
CH2 XLR, 2 pin(Hot)-3 pin(Cold)
150
Ω
MONITOR L
That less than -50 dBu.
(
-50 dBu
以下のこと。)
(3)
CH3 XLR, 2 pin(Hot)-3 pin(Cold)
150
Ω
MONITOR L
That less than -50 dBu.
(
-50 dBu
以下のこと。)
(4)
CH4 XLR, 2 pin(Hot)-3 pin(Cold)
150
Ω
MONITOR L
That less than -50 dBu.
(
-50 dBu
以下のこと。)
(5)
CH5 PHONE, Signal-Ground
150
Ω
MONITOR L
That less than -67 dBu.
(
-67 dBu
以下のこと。)
(6)
CH6 PHONE, Signal-Ground
150
Ω
MONITOR R
That less than -67 dBu.
(
-67 dBu
以下のこと。)
(7)
CH7 PHONE, Signal-Ground
150
Ω
MONITOR L
That less than -67 dBu.
(
-67 dBu
以下のこと。)
(8)
CH8 PHONE, Signal-Ground
150
Ω
MONITOR R
That less than -67 dBu.
(
-67 dBu
以下のこと。)
(9)
CH9 PHONE, Signal-Ground
150
Ω
MONITOR L
That less than -65 dBu.
(
-65 dBu
以下のこと。)
(10) CH10 PHONE, Signal-Ground
150
Ω
MONITOR R
That less than -65 dBu.
(
-65 dBu
以下のこと。)
Measurement condition
(測定条件)
Criteria
(判断基準)
Level control
(LEVEL コントロール)
Max/Min
(最大 / 最小)
OUTPUT Terminal
(出力端子)
Measure the noise Level
(ノイズレベルを測定)
MONITOR
Max
MONITOR L/R
less than -69dBu
(-69dBu 以下のこと)
MASTER
Max
SUBWOOFER
less than -73dBu
(-73dBu 以下のこと)
MONITOR
Min
MONITOR L/R
less than -96dBu
(-96dBu 以下のこと)
MASTER
Min
SUBWOOFER
less than -96dBu
(-96dBu 以下のこと)
2-14. Output noise level
Measure at the signal path (1) - (10) on the Table 2.
Measure the noise level at the output terminals when the
speci
fi
ed resistance is connected to the input terminals.
Table 2
(表 2)
Table 3
(表 3)
2-15. Residual noise level
Execute D-MUTE inspection of diagnostic mode.
Perform measurement with no signal input.
The noise level generated in the output terminal is
measured.
Con
fi
rm that the output noise level is within the speci
fi
ed
below.
SPEAKERS OUT (L/R) : -58 dBu or less
All channels of the input level control volume have to be
set minimum.
The measurements described on the Table 3 have to be
done.
2-16. DC offset
Execute DA-MUTE inspection of diagnostic mode.
Perform measurement with no signal input.
The DC voltage generated in the output terminal is
measured.
SPEAKERS OUT (L/R) : DC 0.0 ± 50 mV
2-14. 出力ノイズレベル
表 2 の (1) 〜 (10) の信号経路を測定します。入力端
子を指定の抵抗値で接続した時の出力端子のノイズ
レベルを測定します。
2-15. 残留ノイズレベル
ダイアグモードの D-MUTE 検査を実行します。
測定は入力無信号の状態で行います。
出力端子に発生するノイズレベルを測定します。
出力ノイズレベルが下記の規定範囲内にあることを
確認します。
SPEAKERS OUT (L/R) : -58
dBu
以下
INPUT CH の LEVEL コントロール ボリュームは
全て最小に設定します。
表 3 の測定を行います。
2-16. DC オフセット
ダイアグモードの DA-MUTE 検査を実行します。
測定は入力無信号の状態で行います。
出力端子に発生する DC 電圧を測定します。
SPEAKERS OUT (L/R) : DC 0.0 ± 50 mV