55
STAGEPAS 600i
2-9. Confirmation for the FAN
Execute FAN inspection of diagnostic mode.
It is con
fi
rmed that the fan rotates and the fan speed changes.
2-10. Confirmation for the detector circuit of the DC
protection
Execute DC PROTECTION inspection of diagnostic
mode.
(1) AMPS circuit board CN512 1pin and 2pin are shorted.
“DC-PROTECTION:ON” is displayed on the DIAG
application.
(2) 1pin and 2pin are opened.
“DC-PROTECTION:OFF” is displayed on the DIAG
application.
2-11. Confirmation for the circuit of the POFF-REQ
Execute POFF-REQ inspection of diagnostic mode.
Con
fi
rm that the POWER LED has to be turned off.
Con
fi
rm that the power supply shall shut down.
2-12. Gain
Set the level control (CH1, MASTER) to the maximum
position, and the MIC/LINE switch to the MIC position.
The signal of -62 dBu is input to CH1 (XLR), and the
output voltage is measured.
Con
fi
rm that the output level is within the speci
fi
ed below.
SPEAKERS OUT(L/R)
: +20.2±2.0 dBu
LEVEL difference L and R : within 2.5dB
Measurement for the mixer section.
Measure the output level at the settings described on the
Table 1.
The measurement have to be done with the SPEAKERS
OUT(L/R) terminal load is disconnected.
2-9. ファンの確認
ダイアグモードの FAN 検査を実行します。
ファンが回転し、回転速度が変わることを確認しま
す。
2-10. DC プロテクション検出回路
ダイアグモードの DC PROTECTION 検査を実行し
ます。
(1) AMPS シートの CN512 の 1 番端子と 2 番端子
をショートさせます。
DIAG アプリケーション上に "ON" が表示されま
す。
(2) 1 番端子と 2 番端子をオープンにします。
DIAG アプリケーション上に "OFF" が表示され
ます。
2-11. POFF-REQ 回路
ダイアグモードの POFF-REQ 検査を実行します。
POWER LED が消灯することを確認します。
電源がシャットダウンすることを確認します。
2-12. 利得
LEVEL コントロール(CH1、MASTER)を最大、
MIC/LINE スイッチを MIC に設定します。
CH1(XLR)に -62 dBu の信号を入力し、出力電圧
を測定します。
出力レベルが下記の規定範囲内にあることを確認し
ます。
SPEAKERS OUT(L/R) : +20.2 ± 2.0 dBu
L/R レベル差
: 2.5dB 以下
ミキサー部の測定
表 1 の設定にした時の出力レベルを測定します。
SPEAKERS OUT(L/R) の負荷抵抗を接続せずに測
定します。