48
STAGEPAS 600i
3-10. A-MUTE inspection
Conduct level check when analog mute (SP OUT side).
Input measuring result on A-MUTE test.
If result is PASS, click “Yes” button.
If result is FAIL, click “No” button.
When determination of the result based on measurement
result by operator is input, the result is displayed in output
window as shown below.
When Normal
Measurement value PASS
PASS: A-MUTE LEVEL
When Abnormal
Measurement value FAIL
FAIL: A-MUTE LEVEL
Troubleshooting
In FAIL, check IC504 (3, 6pin) on a DSP circuit board,
the parts of the circumference of it, and wiring to an
AMPS circuit board.
3-11. DA-MUTE inspection
Conduct level check when DA mute (SP OUT side).
Simultaneously, Conduct level check when DA mute
(MONITOR OUT side).
Input measuring result on DA-MUTE test.
If result is PASS, click “Yes” button.
If result is FAIL, click “No” button.