46
STAGEPAS 600i
3-9. ANALOG inspection
The analog characteristics of MAIN path are inspected. (The
DSP characteristic is a
fl
at)
The analog characteristics of REV-MONITOR path are
inspected. (The DSP characteristic is made into a
fl
at and a
REV-ADC input is assigned to a Moni-DAC output)
The measurement result in the ANALOG test of a MAIN
path is inputted.
If result is PASS, click “Yes” button.
If result is FAIL, click “No” button.
The measurement result in the ANALOG test of a REV-
MONITOR path is inputted.
If result is PASS, click “Yes” button.
If result is FAIL, click “No” button.
When determination of the result based on measurement
result by operator is input, the result is displayed in output
window as shown below.
When Normal
Measurement value
PASS
PASS: MAIN ANALOG LEVEL
or
PASS: REV-MONITOR ANALOG LEVEL
When out of order
Measurement value
FAIL
FAIL: MAIN ANALOG LEVEL
or
FAIL: REV-MONITOR ANALOG LEVEL
3-9. ANALOG
検査
MAIN 経路のアナログ特性の検査を行います。
(DSP
特性はフラット)
REV-MONITOR 経路のアナログ特性の検査を行い
ます。(DSP 特性をフラットにし、REV-ADC 入力
を Moni-DAC 出力にアサインします。)
MAIN 経路の ANALOG テストでの計測結果を入力
します。
結果が PASS の場合、「Yes」ボタンをクリックし
ます。結果が FAIL の場合、「No」ボタンをクリッ
クします。
REV-MONITOR 経路の ANALOG テストでの計測
結果を入力します。
結果が PASS の場合、「Yes」ボタンをクリックし
ます。結果が FAIL の場合、「No」ボタンをクリッ
クします。
オペレータの計測結果に応じた結果判定を入力する
と、検査結果はアウトプットウインドウへ下記のよ
うに表示されます。
正常時
計測値 PASS
PASS: MAIN ANALOG LEVEL
or
PASS: REV-MONITOR ANALOG LEVEL
異常時
計測値 FAIL
FAIL: MAIN ANALOG LEVEL
or
FAIL: REV-MONITOR ANALOG LEVEL