61
STAGEPAS 600i
This firmware updating procedure is applied to
STAGEPAS
600i.
1. Required
Tools
• Personal Computer
DOS/V machine 1 unit
Windows XP SP3 with COM port
(CPU Pentium 500 MHz or above, RAM 256 MB or above)
Windows 7 with COM port
(CPU multi core 1.0 GHz or above,
RAM 1 GB(32 bit)/2 GB(64 bit) or above)
* Check that “Microsoft .NET Framework 2.0 -- the
above –” is installed in a personal computer.
• Serial interface jig set for diagnosis : ZF928400
(USB2UART-CP2102) x 1
A2-SH cable x 1
• USB cable x 1
If the operation system is Windows XP, download the
USB-UART conversion jig driver from the YSISS
homepage.
* For Windows 7, it is recognized as the COM port.
2. Preparation
Download the latest version of application software for
updating from the YSISS homepage and copy them to C
drive of personal computer as shown below.
(URL >> http://plaza.yamaha.co.jp/ysiss/exindex.nsf)
• Application software for updating
C:¥Stagepas¥tools¥Updater¥UpdaterSTAGEPASII.exe
3. Connection
Perform connection as shown in the
fi
gure below.
MIXER ASSEMBLY
PC
USB Cable
(
USB
ケーブル)
CN503
(4P)
CN504
(4P)
(4P)
Serial interface jig set for diagnosis
(ダイアグ用シリアルインターフェース治具セット)
(4P)
A2-SH cable
(
A2-SH
ケーブル)
(USB2UART-CP2102)
: ZF928400
DSP
このファームウェアアップデート手順は、
STAGEPAS
600i
に適用されます。
1. 必要なもの
• パソコン
DOS/V 機 1 台
Windows XP SP3 COM ポート有り
(CPU Pentium 500 MHz 以上、RAM 256 MB 以上 )
Windows 7 COM ポート有り
(CPU マルチコア 1.0 GHz 以上、
RAM 1 GB 以上 (32 bit)/2 GB(64 bit) 以上 )
※ パ ソ コ ン に「Microsoft .NET Framework 2.0
以上」がインストールされていることを確認
します。
• ダイアグ用シリアルインターフェース治具セッ
ト:ZF928400
(USB2UART-CP2102)× 1
A2-SH ケーブル× 1
• USB ケーブル× 1
OS が XP の場合は、USB-UART 変換治具のドラ
イバーを YSISS ホームページからダウンロードし
てください。
※ Windows7 では COM ポートと認識されます。
2. 準備
YSISS ホームページからアップデート用アプリ
ケーションソフトウェアの最新版をダウンロード
し、パソコンの C ドライブに下記のようにコピーし
ます。
(
URL >> http://plaza.yamaha.co.jp/ysiss/exindex.nsf
)
• アップデート用アップリケーションソフトウェア
C: ¥Stagepas ¥tools ¥Updater ¥UpdaterSTAGEPASII.exe
3. 接続
下図のように接続します。
UPDATING
(アップデート)