3 - 50
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a constant voltage charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
Charge the battery until the charging
voltage reaches 15 V.
Leave the battery unused for more than
30 minutes before measuring its open-cir-
cuit voltage.
12.8 V
→
Charging is complete.
12.0
~
12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
This type of battery charger
cannot charge an MF battery. A
variable voltage charger is rec-
ommended.
Charger
Ammeter
Voltmeter
NOTE:
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit volt-
age.
NOTE:
Set the charging time to a max-
imum of 20 hours.
YES
NO
Constant amperage chargers
are not suitable for charging MF
batteries.
CAUTION:
Summary of Contents for Rhino 450 YXR45FAV