9 - 49
–
+
ELEC
TURNS
4. Radiator fan motor
• Disconnect the radiator fan motor coupler.
• Connect the battery (12 V) as shown.
Battery (+) lead
→
Blue terminal
1
Battery (–) lead
→
Black terminal
2
• Check the operation of the radiator fan
motor.
*
DOES NOT TURN
Replace the radiator fan motor.
MEETS
SPECIFICATION
5. Circuit breaker (radiator fan motor)
• Remove the circuit breaker from the wire
harness.
• Connect the pocket tester (
Ω
×
1) to the
circuit breaker.
Circuit breaker resistance
Zero
Ω
at 20 °C (68 °F)
*
OUT OF SPECIFICATION
Replace the circuit breaker.
Summary of Contents for Rhino 450 YXR45FAV
Page 1: ...LIT 11616 19 43 2P5 F8197 10 YXR45FAV SERVICE MANUAL ...
Page 6: ......
Page 57: ...2 31 SPEC OIL FLOW DIAGRAMS 1 Oil delivery pipe 2 Oil pump 3 Oil strainer A A A A 1 2 3 ...
Page 347: ...9 4 ELEC CHECKING THE SWITCHES ...
Page 375: ...9 32 ELEC LIGHTING SYSTEM ...
Page 411: ......
Page 412: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...