3 - 61
CHK
ADJ
CHECKING THE BATTERY
Charging method using a variable voltage charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
NO
YES
Charger
Ammeter
Adjust the voltage to obtain the
standard charging amperage.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “CHECKING THE BAT-
TERY”.
Adjust the charging voltage to
20 ~ 25 V.
Monitor the amperage for 3 ~
5 minutes. Is the standard
charging amperage exceeded?
NO
YES
If the amperage does not
exceed the standard charging
amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check the
charging amperage after 5 hours. If there is any change in the amperage,
readjust the voltage to obtain the standard charging amperage.
Leave the battery unused for more than 30 minutes before measuring its
open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
Set the charging voltage to
16 ~ 17 V. (If the charging
voltage is lower, charging will
be insufficient, if it is higher,
the battery will be over-
charged.)
NOTE:
NOTE:
Summary of Contents for GRIZZLY Ultramatic YFM660FP
Page 1: ...YFM660FP SERVICEMANUAL LIT 11616 15 01 5KM 28197 E0 ...
Page 6: ......
Page 47: ...2 11 SPEC MAINTENANCE SPECIFICATIONS Item Standard Cylinder head tightening sequence ...
Page 347: ...9 3 ELEC CHECKING THE SWITCH ...
Page 407: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...