9 - 49
–
+
ELEC
COOLING SYSTEM
C0NTINUITY
TURNS
4.Fan motor
●
Disconnect the fan motor coupler.
●
Connect the battery (12 V) as shown.
Battery (+) lead
→
Blue terminal
1
Battery (–) lead
→
Black terminal
2
●
Check the operation of the fan motor.
*
DOES NOT TURN
Replace the fan motor.
MEETS
SPECIFICATION
5.Circuit breaker (fan motor)
●
Remove the circuit breaker from the wire
harness.
●
Connect the pocket tester (
Ω ×
1) to the cir-
cuit breaker.
Circuit breaker resistance:
Zero
Ω
at 20 °C (68 °F)
*
OUT OF SPECIFICATION
Replace the circuit breaker.