CL Editor Owner’s Manual
64
3
Module graphic
This area shows a graphic of the PREMIUM rack module that is currently assigned to the rack, and the parameters of
that module. Double-click this to open the module editor for that rack unit. By holding down the <Ctrl>(<
>) key of
your computer keyboard and double-clicking this, you can open multiple rack module editors. For these additional edi-
tors, the rack select buttons are not linked with the RACK popup window of the CL itself.
4
Input meter/Output meter
This indicates the level of the signal that is being input and output from the currently selected PREMIUM rack module.
5
Output patch
Click the CHANNEL field (Click L CHANNEL or R CHANNEL area for the stereo EQ or compressor), and choose one
of the following as the signal route that will be patched to the output channel(s) of the currently selected PREMIUM
rack module.
(*) CL3: 1-64, CL1: 1-48
6
BYPASS
This switches the PREMIUM rack module between active and bypassed states. A PREMIUM rack module is active
when the BYPASS button is dark.
NONE
No assignment
CH 1–72(*)
INPUT CH 1–72(only for rack 1-2(*))
STIN1L–STIN8R
ST IN channel 1–8 L/R (only for rack 1-2)
INS CH 1–72(*)
INPUT CH 1–72(*) insert in
INS MIX 1–24
MIX channel 1–24 insert in
INS MTRX1–8
MATRIX channel 1–8 insert in
INS ST L, INS ST R, INS M(C)
Insert-in of STEREO channel L/R or the MONO channel