3 - 62
CHK
ADJ
CHECKING THE BATTERY
Charging method using a constant voltage charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
NO
YES
Is the amperage higher
than the standard charging
amperage written on the
battery?
Charge the battery until the charging
voltage reaches 15 V.
Leave the battery unused for more than 30
minutes before measuring its open-circuit
voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
This type of battery charger cannot
charge an MF battery. A variable
voltage charger is recommended.
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
NOTE:
Set the charging time to a maxi-
mum of 20 hours.
NOTE:
Constant amperage chargers are
not suitable for charging MF bat-
teries.
CAUTION:
Charger
Ammeter
Voltmeter
Summary of Contents for 5KM2-AE1
Page 1: ...YFM660F P 5KM2 AE1 SERVICEMANUAL 2002 ...
Page 2: ......
Page 8: ......
Page 9: ...GEN INFO 1 ...
Page 11: ...GEN INFO ...
Page 29: ......
Page 30: ...SPEC 2 ...
Page 32: ...SPEC ...
Page 43: ...2 11 SPEC MAINTENANCE SPECIFICATIONS Item Standard Cylinder head tightening sequence ...
Page 73: ...CHK ADJ 3 ...
Page 142: ...ENG 4 ...
Page 146: ...ENG ...
Page 244: ......
Page 245: ...COOL 5 ...
Page 247: ...COOL ...
Page 259: ......
Page 260: ...CARB 6 ...
Page 262: ...CARB ...
Page 270: ......
Page 271: ...DRIV 7 ...
Page 273: ...DRIV ...
Page 306: ...CHAS 8 ...
Page 363: ...ELEC 9 ...
Page 365: ... ELEC 2WD 4WD SELECTING SYSTEM 9 51 CIRCUIT DIAGRAM 9 51 TROUBLESHOOTING 9 52 ...
Page 421: ......
Page 422: ...TRBL SHTG 10 ...
Page 424: ...TRBL SHTG ...