1 - 12
GEN
INFO
CHECKING OF CONNECTIONS
EB801000
CHECKING OF CONNECTIONS
Check the connectors for stains, rust, mois-
ture, etc.
1.Disconnect:
●
Connector
2.Check:
●
Connector
Moisture
→
Dry each terminal with an air
blower.
Stains/rust
→
Connect and disconnect the
terminals several times.
3.Check:
●
Connector leads
Looseness
→
Bend up the pin
1
and con-
nect the terminals.
4.Connect:
●
Connector terminals
NOTE:
The two terminals “click” together.
5.Check:
●
Continuity (using a pocket tester)
NOTE:
●
If there is no continuity, clean the terminals.
●
When checking the wire harness be sure to
perform steps 1 to 3.
●
As a quick remedy, use a contact revitalizer
available at most part stores.
●
Check the connector with a pocket tester as
shown.