Checking the starter relay
1.
Remove the cover and starter relay.
2.
Connect the digital circuit tester to the
starter relay terminals.
3.
Check the starter relay for continuity.
Replace the starter relay if it is not shown
in the chart below.
Checking the neutral switch continu-
ity (EHD)
1.
Disconnect the neutral switch connector.
2.
Connect the digital circuit tester to the
neutral switch connector.
3.
Set the gear shift to “F” or “R” position.
ELEC
8-11
6885J11
Electrical system
68880150
Br
B
1
2
Battery lead
Terminal
position
1
2
Battery connected
Battery disconnected
4.
Check the neutral switch for continuity.
Replace the neutral switch if it is not
shown in the chart below.
Measuring the choke solenoid resis-
tance (ED, ET)
1.
Disconnect the choke solenoid connec-
tor.
2.
Connect the digital circuit tester to the
choke solenoid connector.
3.
Measure the resistance of the choke
solenoid. Replace the choke solenoid if
out of specification.
69R80260
a
b
Br
Br
68880160
L
B
Lead color
Switch position
Brown
Brown
(Br)
(Br)
Free
a
(“F” or “R” position)
Push
b
(“N” position)
Choke solenoid resistance:
3.4–4.0
Ω
at 20°C (68°F)
6885J11_08 07.10.1 9:02 Page 12