ELEC
8-17
6885J11
Electrical systems
6.
Measure the lighting coil resistance.
Replace the stator assembly if out of
specification.
Checking the Rectifier Regulator
NOTE:
Do not use the peak voltage adapter when
measuring the output peak voltage of the
Rectifier Regulator.
1.
Remove the cover.
2.
Connect the digital circuit tester positive
probe to the Rectifier Regulator connec-
tor
1
and connect the negative probe to
the ground.
G
G
/
W
68880170
G
G/W
G
G
B
R
G
R
B
G
/
W
G
/
W
G
/
W
G
/
W
R
G
68880050
R
1
Lighting coil resistance
(reference data):
Green(G)–Green/white (G/W)
0.36–0.54
Ω
at 20°C (68°F)
3.
Measure the Rectifier Regulator output
peak voltage. If less than specification,
measure the lighting coil output peak
voltage. Replace the Rectifier Regulator if
the output peak voltage of the lighting coil
is more than specification.
4.
Remove the Rectifier Regulator from the
power unit.
5.
Connect the digital circuit tester to the
Rectifier Regulator.
6.
Check the Rectifier Regulator for continu-
ity. Replace the Rectifier Regulator if it is
not shown in the chart below.
Measuring condition: Ambient temperature 20°C
(68°F).
B
R
2
3
4
5
G/W
G
68880190
Rectifier Regulator output peak
voltage:
Red (R)–Ground (B)
r/min
Loaded
1,500
3,500
DC V
13
13
Rectifier Regulator continuity:
Tester lead
+
-
G/W
2
R
4
G/W
2
G
3
G/W
2
B
5
0.38–1.155V
G
3
R
4
(reference data)
B
5
R
4
B
5
G/W
2
B
5
G
3
R
4
G/W
2
R
4
G
3
OL
R
4
B
5
(over load)
G
3
G/W
2
G
3
B
5
6885J11_08 07.10.1 9:02 Page 18
Summary of Contents for 55DEHD
Page 4: ......
Page 24: ...GEN INFO 1 19 6885J11 General information MEMO ...
Page 85: ...6885J11 9 8 7 6 5 4 3 2 1 4 16 MEMO ...
Page 154: ...LOWR 6 25 6885J11 Lower unit Shimming T3 M3 M2 68860480 T2 T1 M1 P R F ...
Page 260: ... MEMO ...
Page 261: ... MEMO ...