BRKT
7-43
6885J11
Bracket unit
5.
Remove the O-ring
0
, screws
q
, then
remove the brushes
w
and springs
e
.
c
C
9
Do not pull the PTT motor leads out from
the PTT motor base.
9
Do not deform or damage the bimetal
a
,
otherwise the operation of the circuit
breaker can be affected.
Checking the PTT motor
1.
Check the commutator. Clean with
600–grit sandpaper and compressed air
if dirty.
0
q
w
e
w
e
L
G
a
68870720
6G480220
2.
Measure the commutator diameter.
Replace the armature if below specifica-
tion limit.
3.
Measure the commutator undercut
b
.
Replace the armature if below specifica-
tion limit.
a
1
6F680175
Commutator standard
diameter
a
:
22.0 mm (0.87 in)
Wear limit:
21.0 mm (0.83 in)
Digital caliper
1
:
90890-06704
Standard undercut
b
:
1.8 mm (0.07 in)
Wear limit:
1.3 mm (0.05 in)
6F680180
b