6-21
LOWR
6885J11
Lower unit
Lower unit
2.
Install the Woodruff key
5
onto the drive
shaft groove.
3.
Align the groove
a
in the impeller
6
with
the Woodruff key
5
, and then install the
impeller.
4.
Install the insert cartridge
7
into the
water pump housing
8
.
NOTE:
Align the insert cartridge projection
b
with
the hole
c
in the water pump housing.
5
6
a
68860390
5.
Install the water seal rubber
9
and grom-
met
0
onto the water pump housing
8
,
then install onto the lower case.
c
C
Do not turn the drive shaft counterclock-
wise, otherwise the water pump impeller
may be damaged.
NOTE:
When installing the water pump housing, turn
the drive shaft clockwise while pushing down
the pump housing.
8
7
b
c
68860400
9
0
8
68860410