4.4 Coolant
In order to ensure effective ozone production the ozone generator needs to be cooled.
The coolant must not contain
aggressive or corrosive substances
rust or iron particles
sediment
The following table shows the coolant requirements:
Contents
Unit
Suspended solids
< 1 mg/l
Iron
< 0.3 mg/l
Manganese
< 0.05m g/l
Chloride <
100
mg/l
Conductivity
< 600 µS/cm
Hardness
< 8 ° dH (German hardness)
pH value
6 – 8
4.5 Vibrations
To reduce vibrations generated by the ozone system, various vibration damping components
are included. Amongst others, the following components are installed:
Vibration damping adjustable feet below the skids
Vibration damper elements on critical components within the PSU cabinet.