Options
5.3.6 Option CL (Closed Loop) Cooling Water System
The Closed Loop cooling water system is designed to separate the cooling water circuit
provided by the customer from that of the ozone generator. The SMOevo system features a
CL cooling water system with circulation pump.
BFV330-1
07.0.100
Butterfly valve
Closed loop inlet cooling water isolation valve. Must be
fully open during normal operation.
TI330-1
07.0.105
Temperature
indicator
Indicates closed loop cooling water return temperature.
BV330-1
07.0.110
Ball valve
Make up water line isolation valve. Must be closed
during normal operation.
CKV310-1
07.0.115
Non return valve
Prevents back flow from closed loop cooling water line.
BV330-2
07.0.120
Ball valve
Make up water line isolation valve. Must be closed
during normal operation.
BV310-3
07.0.125
Ball valve
Isolation valve for ET-330. Must be full yopen during
normal operation.
AV330-1
07.0.130
Air relieve valve
Drain valve to vent all air from the water cooling system
during commissioning or in case of maintenance or
service. Must be fully closed during normal operation.
BV330-4
07.0.140
Ball valve
Isolation valve for PI330-1
PI330-1
07.0.135
Pressure indicator
Indicates pressure in expansion tank line.
ET330
07.0.145
Expansion tank
Equalizes fluctuations in closed loop due to thermal
expansion.
BV330-5
07.0.150
Ball valve
Isolation valve for PI330-2.
PI330-2
Pressure indicator
Indicates pressure in closed loop return line upstream
from the pump.
P330
07.0.160
Circulation pump
The pump circulates the cooling water between the
heat exchanger and the ozone generator in the primary
circuit.
BV330-6
07.0.165
Ball valve
Isolation valve for PI330-3 / 07.0.170 and PSH 330-3 /
07.0.175.
PI330-3
Pressure indicator
Indicates pressure in closed loop return line
downstream from the pump.