![Xylem WEDECO EFFIZON SMOevo Series Manual Download Page 20](http://html1.mh-extra.com/html/xylem/wedeco-effizon-smoevo-series/wedeco-effizon-smoevo-series_manual_4680067020.webp)
Manual Ozone Generating System SMOevo
Safety
Rev. 1.0
Page 20 of 91
3.5 Requirements for the Operating Personnel
The operating personnel must read and understand this manual and know the applicable
regulations regarding operational safety and accident prevention.
The operating personnel must accordingly be instructed and trained by the owner / operator
of the system.
Maintenance and repair work may be carried out by qualified personnel only. Only original
spare parts or spare parts approved by the manufacturer may be used
Work on technical equipment may only be carried out by qualified personnel.
Any faults or risks concerning the ozone system immediately must be notified to the owner /
operator of the system or his or her authorized representative.
In addition, observe the following instructions:
Only operate the system in technically perfect condition as well as according to its
intended use, safely and aware of potential hazards.
Rectify any faults immediately which could impair your safety or the safety of the
ozone system.
3.5.1 Personal Protective Equipment
Some work on the system requires protective equipment. The protective equipment must be
provided by the owner / operator of the system.
Observe the following instructions in order to protect your health:
The ozone system produces noise during operation. Using ear plugs or ear muffs is
absolutely necessary.
For some work the use of safety gloves is absolutely necessary.
For some work the use of safety shoes is absolutely necessary.
For some work the use of safety helmets is absolutely necessary.
In addition to this, observe the locally applicable operational safety requirements.
3.5.2 Behavior in Emergency Situations
In case of emergency, follow the following instructions:
Press the Emergency push button immediately.
Exit the operating room immediately in the event of ozone alarm.
In the event of ozone alarm, use the breathing mask only for rescuing injured persons
or for averting other hazards.