Ambient Condition
Values
Ambient temperature for operation
5 °C – 35 °C
1)
Ambient humidity for operation
< 90 % relative humidity
Ambient temperature for transport and storage
0°C to 60°C
2
)
Ambient humidity for transport and storage
< 70 % relative humidity
Ambient air must be free from aggressive substances.
1)
Higher ambient temperatures are possible with special option
2)
Transportation at ambient temperatures of 0 °C are possible with special transport and
storage conditions.
Ensure that the air humidity does not exceed 90% during
continuous operation, higher values are possible for brief
periods (<1h). Ensure that there is no condensation resulting
from moisture (dew) in or on the system.
With regard to EMC emission standards, the system meets the protection requirements for
the industrial sector without restrictions.
When operated in residential, office, business and small scale industrial
sectors, special structural engineering shielding measures may have to be
taken in order to prevent radio interference.
Contact your WEDECO Service for assistance.
Refer to section Contact Addresses.
Special
Safety
Openings to other rooms, e. g. pipe or cable channels must be gas tight or
included in the monitoring process. Openings to rooms in lower levels or
downward stairs are particularly at risk and therefore must imperatively be
included in the safety concept and the monitoring process.