42
EN 5.10 SuSix Manual 2007
FW: 841013-005/843003-001
Turbidity and Suspended Solids Transmitter
Wiring Schematic #2
for "SuSix
®
with Blind Lid and a Magflux
®
with Blind Lid connected to a
common wall mounted Display Unit" on the opposite page (page
).
SuSix
®
with Blind Lid
2-wire, shielded twisted cable
1. Connect lead "1" to slot "Display A"
2. Connect lead "2" to slot "Display B"
3. Connect the twisted shield to slot
"Display -"
Magflux
®
with Blind Lid
2-wire, shielded twisted cable
1. Connect lead "1" to slot "Display A"
2. Connect lead "2" to slot "Display B"
3. Connect the twisted shield to slot
"Display -".
4-wire, shielded twisted cable
1. Connect lead "1" to slot "D"
2. Connect lead "2" to slot "Display A"
3. Connect lead "3" to slot "Display B"
4. Connect the twisted shield to slot
"Display -".
Wall Mounted Display Unit
4-wire, shielded twisted cable
1. Connect lead "1" to slot "D"
2. Connect lead "2" to slot "Display A"
3. Connect lead "3" to slot "Display B"
4. Connect the twisted shield to slot
"Display -".
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
207920
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
Mains
supply
-mA-
-D02-
-D01-
-DI-
-Display-
+
+
A
B
C2 N02
C NO
N01
PE
N
L
-
-
C1
Line
2 wire
shielded cable.
4 wire
shielded cable.
Fuse 24V A
C:
500mA
T
Fuse 115V A
C:
125mA
T
Fuse 230V A
C:
63mA
T
Display unit
Converter #4
Converter #1
Max. four MJK converters with Modbus
can be connected to one display unit:
521268
+DC GND A
B
Pink
Gr
ey
Br
own
Shield
521269
www.mjk.com
DK: +45 45 56 06 56
NO: +47 69 20 60 70
SE: +46 53 31 77 50
NL: +31 251 672171
USA: +1 847 482 8655
AUS: +61 3 9758 8533
1 2 Shield
4 and
shield
1 2 Shield
1 2 3