Appendix D – Replacing Flat Panel Display Bulbs
D-5
9.
While holding the flat panel display up, lift the flange of the bulb assembly over the
locking tab (refer to Figure D-5). as you slide the assembly out. The bulbs are at-
tached to the assembly.
Figure D-5. Model #LQ14X03 - Rear View
1.
Slide in the replacement bulb assembly, making sure it slides securely over the
locking tab.
Note
Xycom recommends replacing both bulbs at the same time.
1.
Repeat steps 9 and 10 for the second bulb assembly.
2.
Reverse steps 1 through 8 to reassemble the unit.
Kyocera 12.1-inch STN Flat Panel Display (#KCB8060BSTT)
3
Turn off the power source.
1.
Unlatch and remove the lid.
2.
If a touchscreen is installed, disconnect the touchscreen cable (TCH1) at the top of
the system board.
3.
Disconnect the KEYPAD1, LEDKB1, and MS2 connectors.
4.
Lay the unit facedown, and remove the four screws holding front panel to the display
adapter plate.
5.
Flip the unit over, lift off the front panel, and set it aside.
(
!!"" # $%&$"