Chapter 3 – Installation
3-27
Figure 3-19. 9465 AC Power Connector.
Perform the following steps to create and attach the cable:
1.
Cut wire cable to the desired length.
2.
Strip 0.25-inch (6 mm) of insulation from the end of the conductor wire. No bare
wire should be exposed when the cable is connected to the workstation.
3.
Tin the wire ends with solder if using stranded wire. This will keep the wire
from fraying.
Warning
When inserting the wire ends of the power cable into the block plug, be
sure there is no exposed wire. Trim the wire ends of the cable or cut a
new cable if necessary.
Figure 3-20. Internal View of 9465 AC Power Connector
4.
Insert the three wire ends of the power cable into the hole of the connector plug.
Bend the Protective Earth ground (PE) wire, the neutral (N) wire, and the line (L)
wire around the corresponding screw. Be sure that no bare wires are exposed.
5.
Tighten the three screws above the wires to hold them firmly in place.
Warning
Never tighten the three screws of the block plug when the cable is con-
nected to a power source. The screws are conductive and have full con-
tact with the cable wire.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for 9465 PC/AT
Page 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 15: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 51: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 71: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...