Screen 42: Alarm
The camera has 4 alarm inputs and 2 alarm outputs.
The actions defined by the user may be associated to an alarm.
The camera has 2 alarm outputs (AUX1& AUX2) which may be programmed to activate
the external devices in the case of alarm. The 2outputs closed to ground.
Option
Value
Explanation
ALARM NUMBER
1 ~ 4
This option allows selecting one of the 4
alarm inputs.
SEQUENCE (SECS)
1 ~ 250
Duration time (in seconds) of the action
related to each alarm when several alarms
occur at the same time.
ALARM ACT
NONE
No action occurs during the alarm.
PRESET
The camera goes to the corresponding
presetting
following
the
alarm
(correspondence is fixed: Alarm 1 - Preset
1; Alarm 2 - Preset 2, etc.).
PATTERN
The alarm performs the corresponding
pattern
following
the
alarm
(correspondence is fixed: Alarm 1 - Pattern
1; Alarm 2 - Pattern 2; etc.)
AUTO SCAN
The camera performs an auto scan after
the alarm: the camera performs a 360
horizontal scan operation.
RANDM SCAN
The camera performs a random scan after
the alarm: the camera performs a random
360° scan pausing for approximately 2”
every
142°.
FRAME SCAN
The camera performs a frame scan after
the alarm: the horizontal scan is performed
in the
SET SCAN
limits.
CRUISE
The camera performs a cruise after the
alarm: the camera runs a cycle of up to 30
preset positions.
TRACKING
The camera performs a tracking operation
after the alarm, starting from the preset
position associated with the alarm. This is
only available for tracking ptz.
ACTIVATE AUX
OFF
No action occurs after the alarm.
AUX1
AUX1
output is activated
alarm: e.g. a siren.
following the
AUX2
AUX2
output is activated following the
45 / 56