24
Oven Installation
For Australia, if installing with a flexible hose assembly, the assembly must be certified to
AS/NZS 1869, and be Class B or D.
For Standard Ovens, if installing with a flexible gas hose, the installation must comply with
either ANSI Z21.69 or CAN/CGA-6.16 and a disconnect device complying with either ANSI
Z21.41 or CAN-6.9.
The installation must conform with local building codes, or in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1, latest version, Natural Gas Installation Code, CAN/
CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2, as applicable.
Gas Supply Requirements for Australian, Standard. & World Ovens
Gas Type
Min kPa
Max kPa
Min “WC
Max “WC
Natural
1.5
3.5
6.0
14
LP
2.75
3.5
11.5
14
The gas supply shall have a gas meter and regulator large enough to handle all of the gas
appliances, such as the furnace, water heater, and ovens in operation at the same time. Add up all
of the Btu/kw/MJ ratings to determine the total load. The installation must conform to local build-
ing codes.
1. The appliance and its individual shutoff valve must be
disconnected
from the gas supply pip-
ing system during any pressure testing of that system at test pressures in
excess
of 3.5 kPa or
½-psi.
2. The appliance must be
isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test pres-
sures
equal to or less than
3.45 kPa or ½-psi.
Minimum and maximum inlet pressures are as follows:
All installations must conform to local building and mechanical codes.
NOTE
Summary of Contents for 1832-AE-B
Page 43: ...43 This page intentionally left blank ...
Page 88: ...This page intentionally left blank ...
Page 95: ...95 Oven Schematic 1832 2440 3240 3255 3855 Square Burner Standard ...
Page 96: ...96 Oven Schematic 1832 2440 3240 3255 3855 Square Burner World ...
Page 97: ...97 Oven Schematic 1832 2440 3240 3255 3855 Round Burner Australia ...
Page 98: ...98 Oven Schematic 3270 3870 Square Burner Standard RH Control Box ...
Page 99: ...99 3270 3870 Square Burner Standard LH Control Box Oven Schematic ...
Page 100: ...100 Oven Schematic 3270 3870 Square Burner World RH Control Box ...
Page 101: ...101 Oven Schematic 3270 3870 Square Burner World LH Control Box ...
Page 102: ...102 3270 3870 Round Burner Australia LH Control Box Oven Schematic ...
Page 103: ...103 Oven Schematic 3270 3870 Round Burner Australia RH Control Box ...
Page 104: ...104 Hood Schematic Standard ...
Page 105: ...105 Hood Schematic World ...