16
Do not use Teflon tape on gas line connections as this can possibly cause gas valve
malfunction or plugging of orifices from shreds of tape. Use of Teflon tape may af-
fect warranty.
FOR EACH OVEN:
Electrical service for Standard Ovens must be 120VAC, 20 A, 60 Hz single phase circuits
with ground.
Electrical service for World Ovens must be 220/230/240VAC, 10 A, 50/60 Hz single phase
circuits with ground.
Electrical service for Australian Ovens must be 220/230/240 VAC, 10 A, 50Hz single
phase and installed in accordance with the latest version of AS/NZS 3000 wiring rules.
A separate circuit breaker must be provided for each oven deck.
Gas and electric connections must be accessible when the ovens are in the installed position.
Electrical plugs and cords must meet all local code requirements.
Gas hose assemblies with quick disconnects for each oven deck will be installed at each valve.
Oven Only Rough-In Specifications
Item # Description
1
1-½ [40] Shut-Off Valve
2
¾ [20] Shut-Off Valve
3
6 [150] Nipple
4
¾ [20] Nipple
5
Reducing Tee
6
Tee
7
Cap
8
Plug
All pipe fittings to be 1-½ [40] minimum
unless noted. NPT & BSP
1
3
2
4
5
6
7
8
3
3
4
CAUTION
NOTE
NOTE: All dimensions in inches [mm].
Summary of Contents for 1832-AE-B
Page 43: ...43 This page intentionally left blank ...
Page 88: ...This page intentionally left blank ...
Page 95: ...95 Oven Schematic 1832 2440 3240 3255 3855 Square Burner Standard ...
Page 96: ...96 Oven Schematic 1832 2440 3240 3255 3855 Square Burner World ...
Page 97: ...97 Oven Schematic 1832 2440 3240 3255 3855 Round Burner Australia ...
Page 98: ...98 Oven Schematic 3270 3870 Square Burner Standard RH Control Box ...
Page 99: ...99 3270 3870 Square Burner Standard LH Control Box Oven Schematic ...
Page 100: ...100 Oven Schematic 3270 3870 Square Burner World RH Control Box ...
Page 101: ...101 Oven Schematic 3270 3870 Square Burner World LH Control Box ...
Page 102: ...102 3270 3870 Round Burner Australia LH Control Box Oven Schematic ...
Page 103: ...103 Oven Schematic 3270 3870 Round Burner Australia RH Control Box ...
Page 104: ...104 Hood Schematic Standard ...
Page 105: ...105 Hood Schematic World ...